.Patch Deployment vAdeptia_Connect_v3.3

Adeptia regularly releases a patch with updated features and enhancements. You need to apply the patch both on the production and disaster recovery environments for latest enhancements. You must to deploy the patch first on the production environment then on disaster recovery environment. 

Applying Patch

Prerequisites

Ensure that:

  • You have Read and Write permissions on all sub-folders and files of .../AdeptiaConnect-<Version>.
  • Services such as Kernel, WebRunner, and AIMap are stopped.
  • No process flow or transaction should be in running, waiting or queued state. 
  • Latest License details of Adeptia Connect. You can contact Adeptia Support for more details.

Steps to apply the patch:

For Windows:

  1. Download the latest patch from the provided URL.
  2. Extract the downloaded zip file in a folder.
  3. Open the Command Prompt.
  4. Go to the folder where you have extracted the zip file.
  5. Run the following command to apply the patch:
    Apply-Patch.bat "<Path where Adeptia Connect is installed till AdeptiaServer folder>" 

    For example:

    Apply-Patch.bat "
    C:/Program Files/AdeptiaConnect/AdeptiaSuite-x.x/ConnectServer/AdeptiaServer"

    Once the patch is applied, a confirmation message will be displayed.

    Note: While applying the patch you may come across following warning messages that you should ignore.

    Warning: Not deploying connect2.0 accelerator because no change list is present.
    Warning: Not deploying EDI accelerator because no change list is present.

  6. Start Kernel, WebRunner, and AIMap. 


For Linux:

  1. Open the Terminal.
  2. Download the latest patch from the provided URL.
  3. Extract the downloaded zip file in a directory.
  4. Go to the directory where you have extracted the zip file.
  5. Run the following command to apply the patch:

    ./Apply-Patch.sh <Path where Adeptia Connect is installed till Adeptia Server folder> 

    For example:

    ./Apply-Patch.sh /mnt/AdeptiaConnect-x.x/ConnectServer/AdeptiaServer

    Once the patch is applied, a confirmation message will be displayed.

    Note: While applying the patch you may come across following warning messages that you should ignore.

    Warning: Not deploying connect2.0 accelerator because no change list is present.
    Warning: Not deploying EDI accelerator because no change list is present.

  6. Start Kernel, WebRunner, and AIMap.

  • Patch application may take some time, in case there are a large number of records in the backend and log database. 
  • A PatchApplicationLog<Date>.log file is also created inside the logs folder. The logs folder is available in the same folder from where you have applied the patch. PatchApplicationLog_<Date>.log file contains the logs generated during patch application and can be used to troubleshoot any issue related to the patch application. 
  • After applying the patch, clear the browser history before login to Adeptia Suite. 
  • Clear the Java cache and the previous certificate of Adeptia from Java Control Panel. Click here to know how to clear Java cache and delete Adeptia certificates.
  • If any error occurs during patch deployment then the patch will be recovered automatically.