abpm.dataMapper.minHeapsize

Minimum memory required for the Data Mapper applet. Indicates the minimum amount of Java memory reserved by Data Mapper applet. This memory is used on the client machine where Data Mapper applet is loaded.

256MB

Memory in MBs.

abpm.dataMapper.maxHeapsize

Maximum memory assigned to Data Mapper applet. Indicates the maximum amount of Java memory that can be used by Data Mapper applet. This memory is used on the client machine where Data Mapper applet is loaded. If you load a very large schema in data mapper, then you may increase this value as per the size of schema and memory available on the machine where data mapper is loaded.

512MB

Memory in MBs.

abpm.dataMapper.readTimeOut

Maximum time in seconds before throwing error while waiting for getting a response from the server. This is the maximum time for which the data mapper applet waits, before throwing an error message in case of a problem such as a backend database server is down.

720

Any positive integer

abpm.dataMapper.enableTipOfTheDay

Enable or Disable tip of the Day.

false

True/False or Yes/No

abpm.dataMapper.httpScheme

HTTP scheme for Data Mapper.

 

HTTPS or HTTP

abpm.dataMapper.dateFunction.logError

Log Error for Data Mapper Date functions.

true

true or false

abpm.dataMapper.saxon.dtdValidation.enable

Enable or disable DTD validation for mapping.

Yes - Saxon parser will retrieve and validate DTD for mapping.

No - Saxon parser will not retrieve and validate DTD for mapping.

no

yes or no

abpm.dataMapper.filterEmptyElements

Enable to filter empty elements in the output of Data Mapper.

 

 

abpm.dataMapper.dateFormat.validate

Parse invalid dates in the date format function available in the data mapping.

yes - Date format function in the data mapper will parse invalid dates and will not give a blank output.

no - Date format function in the data mapper will not parse invalid dates and gives a blank output. 

yes

yes or no

 

MONITORING

Property Name

Description

Default Value

Possible Values

Property Name

Description

Default Value

Possible Values

abpm.monitoring.minHeapsize

The minimum memory required for the System Monitoring applet. This indicates the minimum amount of Java memory reserved by the Monitoring applet. This memory is used on the client machine where the System Monitoring applet is loaded.

256MB

Memory in MBs

abpm.monitoring.maxHeapSize

The maximum memory that can be assigned to System Monitoring applet. This indicates the maximum amount of java memory that can be used by System Monitoring applet. This memory is used on the client machine where System Monitoring applet is loaded.

512MB

Memory in MBs

abpm.monitoring.readTimeOut

Maximum time in seconds before throwing error while waiting for getting a response from the server. The maximum time for which the monitoring applet waits, before throwing an error message in case of a problem such as a backend database server is down.

720

Any positive integer

abpm.monitoring.httpScheme

HTTP scheme for Monitoring Applet. If Adeptia Suite is running in a secure mode then you have to set this value to HTTPS.

 

HTTPS or HTTP



PROCESS DESIGNER

Property Name

Description

Default Value

Possible Values

Property Name

Description

Default Value

Possible Values

abpm.processDesigner.minHeapsize

The minimum memory required for the Process Designer applet. This indicates the minimum amount of Java memory reserved by the Process Designer applet. This memory is used on the client machine where the Process Designer applet is loaded.

256MB

Memory in MBs

abpm.processDesigner.maxHeapSize

The maximum memory that can be assigned to Process Designer applet. This indicates the maximum amount of java memory that can be used by Process Designer applet. This memory is used on the client machine where Process Designer applet is loaded.

512MB

Memory in MBs

abpm.processDesigner.readTimeOut

Maximum time in seconds before throwing error while waiting for getting a response from the server. The maximum time for which Process Designer applet waits, before throwing an error message in case of a problem such as a backend database server is down.

720

Any positive integer

abpm.processDesigner.httpScheme

HTTP scheme for Process Designer applet. If Adeptia Suite is running in a secure mode then you have to set this value to HTTPS.

 

HTTPS or HTTP


DASHBOARD

Property Name

Description

Default Value

Possible Values

Property Name

Description

Default Value

Possible Values

abpm.dashboard.httpScheme

HTTP scheme for Dashboard. If Adeptia Suite is running in a secure mode then you have to set this value to HTTPS.

HTTP

HTTPS or HTTP

 

REPORT

Property Name

Description

Default Value

Possible Values

Property Name

Description

Default Value

Possible Values

abpm.report.httpScheme

HTTP scheme for Reports. If Adeptia Suite is running in a secure mode then you have to set this value to HTTPS.

 

HTTPS or HTTP