An event may not be fired at the scheduled time due to multiple reasons. These are outlined as:
- No thread is available (refer to org.quartz
Anchor _Hlt176332424 _Hlt176332424 .thAnchor _Hlt186990172 _Hlt186990172 Anchor _Hlt186990175 _Hlt186990175 readPool.threadCount property in the Administrator guide)available - System is busy
When the event is not fired at the scheduled time, it is considered as a delayed event. The delayed event is fired, when the thread becomes available or the system is not too busy. This delayed event is fired as long as delay is not more than misfire threshold. If delay is more than the misfire threshold, event is considered as a misfired event. The misfire threshold is specified by following parameter defined in quartz.properties file:
org.quartz.jobStore.misfireThreshold = 10000
10000 = 10 Seconds
10 seconds is the default value of misfire threshold, which can be changed, based on your requirements.
Setting the Action on Misfire Event property
The process of changing the advanced properties of a File Event is setting for the Action on Misfire Event property of an event, for example, file event, is explained below.
To change the permission of an activity:
Image Removed
Click Configure > EVENTS > File.
On the File Event manage page:
Click More menu and then click Edit for the
specific event you want to edit.
On the Edit File Event page,
expand the Advanced Properties
.
Image AddedIn the Action on Misfire Event field, select the option Run Once to enable handling of misfire of the file event.
Note The Run Once option will run only one collective instance of all the misfires for a particular event. The Ignore Misfire option will not run a misfired event.
The default value for Action on Misfire Event field is set to
Ignore Misfire.
Panel | ||||
---|---|---|---|---|
| ||||