Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

This section lists the prerequisites and explains how to apply the patch.

Prerequisites

...

Before applying the patch, ensure that you have

  • Deactivated any running Mail Events before applying the patchEvent.
  • Before applying the patch, it is recommended to take the Taken the backup of the database that is used as a backend by Adeptia Suitebackend database
    • In case, the embedded database is used as the backend, follow the below steps to take the backup:
      1. Stop Kernel and WebRunner.
      2. Go to .../<AdeptiaInstallFolder>/AdeptiaServer/ServerKernel folder.
      3. Copy the embeddedDB folder and keep it into a separate folder.
    • In case any other database is used as
  • a
    • the backend database, you need to follow the backup
  • instruction

...

  • Read and Write permissions on all subfolders and files of ../AdeptiaSuite-<Version>

...

  • .

...

  • Stopped Kernel and Webrunner.
  • Stopped process flows that are in Running or Queued state.

Applying Patch

Following are the high-level steps to apply the patch.For Windows

  1. Download the latest patch from the provided URL.
  2. Extract the downloaded zip file in a folder.
  3. Open the Command Prompt and change .
  4. Go to the folder where you have extracted the patch zip file.
  5. Depending on the operating system you are using, run one of the following commands:
    For Windows Run the following command to apply the patch:
    Apply-Patch.bat "<Path where Adeptia Suite is
    installed.>
     installed till AdeptiaServer folder>" 

    ExampleFor example: 

    Apply-Patch.bat "C:
    \
    /Program Files
    \
    /AdeptiaSuite
    \
    /AdeptiaSuite-
    <version>\AdeptiaServer"
    x.x/AdeptiaServer"

    Once the patch is applied, a confirmation message will be displayed.

  6. Restart Kernel and WebRunner. 

    Info
     

 

For

...

Linux 

 

  1. Open the Terminal.
  2. Download the latest patch from the provided URL.
  3. Extract the downloaded zip file in a folder.
  4. Go to the directory where you have extracted the zip file.
  5. Run the following command to apply the patch:

    ./Apply-Patch.sh <Path where Adeptia Suite is installed
    .> 

     

    This will apply the patch. This will also apply the B2Bi accelerator, in case, you have applied the patch with updated B2Bi accelerator
     till Adeptia Server folder> 

    For example:

    ./Apply-Patch.sh /mnt/AdeptiaSuite-x.x/AdeptiaServer

    Once the patch is applied, a confirmation message will be displayed.

  6. Restart Kernel and WebRunner.


Info
  • Patch application may take

...

  • some time

...

  • , in case there are a large number of records in the backend and log

...

  • database.
  • PatchApplicationLog<Date>.log file is also created inside the logs folder. The logs folder is available in the same folder from where you have applied the patch

...

  • PatchApplicationLog_<Date>.log file contains the

...

  • logs generated during patch application and

...

  • can be used to troubleshoot any issue related to the patch application

...

    

info
  • .

...


  • After applying the patch, clear the browser history before login to Adeptia Suite.
  • Clear the Java cache and the previous certificate of Adeptia from Java Control Panel. To know how to clear Java cache and delete Adeptia certificates, refer to http://support.adeptia.com/entries/72486986-Deleting-Java-Cache-and-Certificates
  • If any error occurs during patch deployment then the patch will be recovered automatically recovered.